How to Train on the EYESI Simulator the Smart Way

A simulator is only as good as the way you use it. In this video Dr. Ivo Ferreira, a mentor who dedicates his life to helping surgeons at any stage raise their level, walks through the EYESI cataract simulator from Haag-Streit Simulation: the hardware, the software and curriculum, the feedback, and the checklist he wants every trainee to follow.
The values in this post are the ones the mentor uses in the video, on his machine. Settings change with each platform and each case: use them as a reference and adjust them with your own mentor.
Why simulate at all
Simulation is the bridge between theory and knowledge and the operating room. Dr. Ferreira believes simulation should be present at every stage, in every operating room: surgeons should behave like airline pilots, simulating all the time, with mandatory sessions two or three times a year for the things they do not do often. And for anyone who wants to learn a new technique, the simulator is the place to do it. If you want to see what the evidence says, read our meta-analysis on virtual reality training.
Know the hardware
The simulator has a table with the patient's head, a microscope, a computer that runs the simulation, two foot pedals and an interactive touch screen. Once it is on, the screen shows whether the simulator is connected to the network; when it is green, your data goes to the cloud, so you can see your metrics on your phone and your mentor can see them too and assign you curriculums. The same machine also does retina, but this video focuses on the cataract curriculum.
- Microscope: set the eyepieces to zero, then adjust your interpupillary distance correctly. You can change the angle of the microscope, but he strongly recommends always using the same position.
- Head: choose a frontal or a temporal approach; this changes everything, and it is also set in the software.
- Instruments: three delicate instruments with sensors inside, including rotational sensors. The yellow one, angled, is mostly the second instrument and for injecting viscoelastic. One is held as forceps or scissors. The red one, straight, is the handpiece, with irrigation and more. Keep the cables untangled: a dropped instrument is a big problem.
- Protect the handpieces: before each task, look from outside the microscope, grab the instrument correctly, find the incision or paracentesis (a hole in the physical eye), enter, and only then go to the microscope.
- Foot pedals: one for the microscope (focus, zoom, X and Y) and one for the phaco machine (positions one, two and three), with side switches to change function, for example from sculpting to quadrant removal, and reflux.
- Table height: adjust it to your ergonomics and stature.
The software and the curriculum
You log in with your own user and password. The curriculum the mentor assigns has four stages, A, B, C and D, and ends with the Cataract Challenge.
- VRMNet items are videos you watch on your phone, away from the simulator. They turn green when you have watched them and, sometimes, passed the questionnaire.
- Locks: to move on, you must show consistency of performance, with scores of 50, then 60, then 70, then 80 in two tasks in a row.
- You can see your courseware progress, download reports to a USB drive and, in settings, choose frontal or temporal approach and where to place the main incision and the two paracenteses (130 degrees for the main incision in the demonstration).
- Navigation is intuitive: forward is in the lower right, back is in the upper left. The interface also comes in Spanish, French, Russian and Chinese.
The curriculum goes as far as very advanced tasks: capsulorhexis manoeuvres, weak zonules, auxiliary devices, white cataracts and anterior vitrectomy. Training anterior vitrectomy before you ever face it in the operating room is a powerful idea.
Feedback is the most important thing
One of the key values of simulation is to deconstruct a task and approach it step by step. But Dr. Ferreira's favourite part is the objective feedback: a score that explains what went right and what went wrong, plus a replay with augmented features.
In his demonstration he deliberately makes mistakes in an anterior chamber task: touching the endothelium or the lens, operating with a tilted eye, pressing too much on the incision (the incision opening is shown in the upper left). The feedback then says the objective was not achieved, scores efficiency, and flags the odometer and eye tilt. Press the "i" to see exactly what the task wanted. The time-lapse shows each mistake where it happened and how many points it cost. His message: always, always go to the feedback. You cannot improve what you do not measure, and immediate, objective feedback is the most powerful way for the brain to learn something new.
The checklist: behave like a pilot
Cataract surgeons need a checklist for everything and a lot of structure. On the simulator the checklist is:
- Ergonomics. A chair whose height you can control; sit back, take care of your lumbar and cervical spine (what he calls the gorilla position), 90 degrees at the elbows, and the hands as close as possible to 90 degrees as well.
- Visualization. Eyepieces at zero, interpupillary distance, then focus. With the microscope pedal you have focus, zoom and even light intensity, and you can switch the room lights on and off.
- Instruments and consumables. The red handpiece is phaco, but the second instrument can be changed: vertical chopper, safety chopper (a sabre), horizontal chopper or push-pull. In capsulorhexis you can choose air, trypan blue, BSS, viscoelastic and cystotome; in anterior vitrectomy, triamcinolone.
- Machine settings. Bottle height for irrigation; vacuum and flow for aspiration; peristaltic or venturi pump (a venturi pump has no flow setting, you only control vacuum); continuous irrigation exists, but he does not recommend it in simulation because you need to train your foot pedal; ultrasound as continuous, pulse or burst. You can save presets.
- Hand biomechanics. A fixation point with three fingernails on the patient's forehead (the crab claw), different grips for the handpiece and for the second instrument, and the ability to pivot and float through the incision without moving the eye.
The presets he shows
- Sculpting, hard cataract: power 70, low vacuum, low flow.
- Quadrant removal: high power but not as high as sculpting, burst mode, vacuum 450 and high flow, because he wants the fluidics to do the job.
- Irrigation/aspiration: high and high, no ultrasound.
- Anterior vitrectomy: low bottle, low vacuum, low flow, high cut rate.
What a real simulated case looks like
With a temporal approach he sculpts and cracks, then removes quadrants with little ultrasound and high vacuum to hold the nucleus. A superficial horizontal chop and a chamber collapse remind you how dynamic the environment is; then a vertical chop, careful not to pull on the zonule. With a hard cataract, he creates space to bring the first fragment to the safety zone instead of fighting it. It is not only about the settings, but how you deliver them with your foot. In a capsulorhexis task he shows that poor incision management makes you lose viscoelastic. And at the end, always: the score and the time-lapse.
Key takeaways
- Simulation is the bridge to the operating room, at every stage of your career.
- Master the hardware first: microscope, head, delicate instruments, pedals and table height.
- Advance through A, B, C and D only with consistent scores; watch the VRMNet videos on your phone.
- Always go to the feedback and the time-lapse: you cannot improve what you do not measure.
- Follow the checklist: ergonomics, visualization, instruments and consumables, machine settings, hand biomechanics.
- Pivot and float; do not move the eye.
Learn phaco step by step: read the complete phaco training guide and watch more on the PhacoMentors YouTube channel.
Want a mentor on your own cases? PhacoMentors Premium gives you a personal roadmap, video feedback on your surgeries and a monthly call with a mentor, for $6 a month.
Your personal roadmap from the stage where you are today, video feedback on your own surgeries and a monthly call with Dr. Ivo Ferreira or an OU mentor. $6 a month.
Go Premium